Pump units of 1-ANGK type are used for pumping fluids of up to +200 C.
For liquids with temperature up to +400 C 2-ANGK pump type are applied.
Parameter | 1, 2-ANGK |
---|---|
Speed, rpm | 1500, 3000 |
Flow, m3/h | from 6 to 1000 |
Head, m | from 50 to 130 |
Power, kW | up to 500 |
Casing pressure, PN, kg/cm2 | 50 |
Temperature, C (up to) | up to 200, up to 400 |
Service life, h (no less than) | 40 000 |
Life cycle, y (no less than) | 20 |
Pump designation | Flow, m3/h | Head, m | NPSH, Δh, m | Nominal diameter of impeller, mm | DN suction pipe, mm | DN discharge pipe, mm |
---|---|---|---|---|---|---|
1(2)-ANGK-2.15/30 | 12,5 | 35 | 3 | 160 | 50 | 40 |
1(2)-ANGK-3.15/50 | 12,5 | 50 | 3,3 | 200 | 50 | 40 |
1(2)-ANGK-4.15/80 | 12,5 | 80 | 3,5 | 250 | 50 | 40 |
1(2)-ANGK-6.30/30 | 25 | 32 | 2,7 | 160 | 80 | 50 |
1(2)-ANGK-7.30/50 | 25 | 50 | 2,5 | 200 | 80 | 40 |
1(2)-ANGK-8.30/80 | 25 | 80 | 3,8 | 250 | 80 | 40 |
1(2)-ANGK-9.30/130 | 25 | 125 | 4,7 | 315 | 80 | 40 |
1(2)-ANGK-11.60/30 | 50 | 32 | 3,5 | 160 | 100 | 80 |
1(2)-ANGK-12.60/50 | 50 | 50 | 2,9 | 200 | 80 | 50 |
1(2)-ANGK-13.60/80 | 50 | 80 | 2,6 | 250 | 80 | 50 |
1(2)-ANGK-14.60/130 | 50 | 125 | 4,3 | 315 | 80 | 50 |
1(2)-ANGK-16.90/30 | 100 | 32 | 4,6 | 160 | 100 | 80 |
1(2)-ANGK-17.90/50 | 100 | 50 | 3,9 | 200 | 100 | 80 |
1(2)-ANGK-18.90/80 | 100 | 80 | 3,9 | 250 | 100 | 80 |
1(2)-ANGK-19.90/130 | 100 | 125 | 3,8 | 315 | 100 | 80 |
1(2)-ANGK-20.150/30 | 160 | 32 | 4,9 | 160 | 150 | 80 |
1(2)-ANGK-21.150/50 | 160 | 50 | 5,8 | 200 | 150 | 80 |
1(2)-ANGK-22.150/80 | 160 | 80 | 6,3 | 250 | 150 | 80 |
1(2)-ANGK-23.150/130 | 160 | 125 | 4,3 | 315 | 150 | 80 |
1(2)-ANGK-26.200/50 | 250 | 50 | 5,6 | 200 | 150 | 100 |
1(2)-ANGK-27.200/80 | 250 | 80 | 5,8 | 250 | 150 | 100 |
1(2)-ANGK-28.200/130 | 250 | 125 | 5,9 | 315 | 150 | 100 |
1(2)-ANGK-39.450/50 | 500 | 50 | 5,2 | 400 | 250 | 200 |
1(2)-ANGK-40.450/80 | 500 | 80 | 4,5 | 500 | 250 | 200 |
1(2)-ANGK-41.800/50 | 800 | 50 | 6,2 | 400 | 300 | 250 |
1(2)-ANGK-42.800/80 | 800 | 80 | 6,8 | 500 | 300 |
250 |
The diagrams are given as an example. If required, other pump parameters can be provided.